{"id":4573,"date":"2025-04-30T14:47:52","date_gmt":"2025-04-30T07:47:52","guid":{"rendered":"https:\/\/www.petrosync.com\/blog\/?p=4573"},"modified":"2025-06-19T11:07:47","modified_gmt":"2025-06-19T04:07:47","slug":"radiographic-testing","status":"publish","type":"post","link":"https:\/\/www.petrosync.com\/blog\/radiographic-testing\/","title":{"rendered":"Radiographic Testing Explained for Industry"},"content":{"rendered":"<div id=\"bsf_rt_marker\"><\/div><p class=\"ai-optimize-6 ai-optimize-introduction\">In industries where safety, precision, and compliance are paramount\u2014such as <a href=\"https:\/\/www.petrosync.com\/blog\/oil-and-gas\/\">oil and gas<\/a>, <a href=\"https:\/\/www.petrosync.com\/blog\/what-is-petrochemical\/\">petrochemical<\/a>, and manufacturing\u2014<a href=\"https:\/\/www.petrosync.com\/blog\/what-is-ndt\/\">non-destructive testing (NDT)<\/a> methods are critical for maintaining asset integrity. One of the most reliable methods to detect internal flaws is Radiographic Testing (RT).<\/p>\n<p class=\"ai-optimize-7\">Many industries still rely on RT in inspection scenarios, especially when surface-based methods can\u2019t detect internal, volumetric defects. Let\u2019s explore what radiographic testing is, how it works, and how you can build expertise in this vital technique.<\/p>\n<h2 class=\"ai-optimize-8\">What is the Radiographic Testing?<\/h2>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-large wp-image-4575\" src=\"https:\/\/www.petrosync.com\/blog\/wp-content\/uploads\/2025\/04\/H2-Radiographic-testing-1024x536.webp\" alt=\"Radiographic testing\" width=\"770\" height=\"403\" srcset=\"https:\/\/www.petrosync.com\/blog\/wp-content\/uploads\/2025\/04\/H2-Radiographic-testing-1024x536.webp 1024w, https:\/\/www.petrosync.com\/blog\/wp-content\/uploads\/2025\/04\/H2-Radiographic-testing-768x402.webp 768w, https:\/\/www.petrosync.com\/blog\/wp-content\/uploads\/2025\/04\/H2-Radiographic-testing-1536x804.webp 1536w\" sizes=\"(max-width: 770px) 100vw, 770px\" \/><\/p>\n<p class=\"ai-optimize-9\"><a href=\"https:\/\/www.petrosync.com\/blog\/radiographic-testing\/\">Radiographic Testing (RT) is<\/a> a non-destructive testing technique used to inspect the internal structure of materials, particularly metals and welds, without damaging the component itself. The method uses X-rays or gamma rays to penetrate solid objects and produce an image (radiograph) that reveals subsurface discontinuities.<\/p>\n<p class=\"ai-optimize-10\">Radiographic Testing is widely used to detect:<\/p>\n<ul>\n<li class=\"ai-optimize-11\">Cracks<\/li>\n<li class=\"ai-optimize-12\"><a href=\"https:\/\/www.petrosync.com\/blog\/what-is-porosity\/\">Porosity<\/a><\/li>\n<li class=\"ai-optimize-13\">Incomplete fusion in welds<\/li>\n<li class=\"ai-optimize-14\">Shrinkage cavities in castings<\/li>\n<\/ul>\n<p class=\"ai-optimize-15\">Because of its ability to detect defects deep within materials, Radiographic Testing is a preferred method in pipeline inspections, <a href=\"https:\/\/www.petrosync.com\/blog\/pressure-vessel\/\">pressure vessel<\/a>, aircraft components, and nuclear systems. Its detailed imaging makes it one of the most accurate and auditable NDT methods available.<\/p>\n<h2 class=\"ai-optimize-16\">How Radiographic Testing Works<\/h2>\n<p class=\"ai-optimize-17\">Radiographic Testing operates on the principle of differential absorption of radiation. Here\u2019s a simplified breakdown of the process:<\/p>\n<p class=\"ai-optimize-18\">1. A radiation source (either an X-ray tube or a radioactive isotope like Iridium-192 or Cobalt-60) emits rays toward the object under test.<\/p>\n<p class=\"ai-optimize-19\">2. The rays pass through the material and are partially absorbed depending on the material\u2019s thickness and density.<\/p>\n<p class=\"ai-optimize-20\">3. Behind the object, a detector (such as radiographic film or a digital panel) captures the intensity of the rays that pass through.<\/p>\n<p class=\"ai-optimize-21\">4. The result is a radiograph\u2014an image showing internal features, where darker areas indicate thinner or less dense regions, possibly suggesting voids or cracks.<\/p>\n<p class=\"ai-optimize-22\">The success of RT relies heavily on material type, object geometry, radiation energy, and exposure duration. A trained technician is essential to interpret these images accurately and determine whether a component passes inspection.<\/p>\n<p class=\"ai-optimize-23\"><a href=\"https:\/\/www.petrosync.com\/drilling-and-well-enginering?leads_source=blog&amp;product=F&amp;campaign=Artikel&amp;keyword=Radiographic+Testing+Explained+for+Industry\"><img decoding=\"async\" class=\"alignnone wp-image-4576 size-large lazyload\" data-src=\"https:\/\/www.petrosync.com\/blog\/wp-content\/uploads\/2025\/04\/CTA-Radiographic-testing-1024x431.webp\" alt=\"\" width=\"770\" height=\"324\" data-srcset=\"https:\/\/www.petrosync.com\/blog\/wp-content\/uploads\/2025\/04\/CTA-Radiographic-testing-1024x431.webp 1024w, https:\/\/www.petrosync.com\/blog\/wp-content\/uploads\/2025\/04\/CTA-Radiographic-testing-768x323.webp 768w, https:\/\/www.petrosync.com\/blog\/wp-content\/uploads\/2025\/04\/CTA-Radiographic-testing-1536x647.webp 1536w\" data-sizes=\"(max-width: 770px) 100vw, 770px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 770px; --smush-placeholder-aspect-ratio: 770\/324;\" \/><\/a><\/p>\n<h2 class=\"ai-optimize-24\">Tools and Equipment Used in Radiographic Testing<\/h2>\n<p class=\"ai-optimize-25\">The effectiveness of radiographic testing depends significantly on the quality of equipment and proper setup. The main tools used include:<\/p>\n<h3 class=\"ai-optimize-26\">1. Radiation Sources<\/h3>\n<ul>\n<li class=\"ai-optimize-27\">X-ray generators: Used for precise, controlled testing in laboratories or field setups.<\/li>\n<li class=\"ai-optimize-28\">Gamma-ray sources: Iridium-192 and Cobalt-60 are commonly used in industrial applications due to their portability.<\/li>\n<\/ul>\n<h3 class=\"ai-optimize-29\">2. Imaging Media<\/h3>\n<ul>\n<li class=\"ai-optimize-30\">Radiographic Film: Traditional method that requires development in a darkroom.<\/li>\n<li class=\"ai-optimize-31\">Computed Radiography (CR): Uses phosphor plates that are scanned digitally.<\/li>\n<li class=\"ai-optimize-32\">Digital Radiography (DR): Direct digital capture using flat-panel detectors; faster and eco-friendly.<\/li>\n<\/ul>\n<h3 class=\"ai-optimize-33\">3. Support Tools<\/h3>\n<ul>\n<li class=\"ai-optimize-34\">Collimators: Direct and shape radiation beams.<\/li>\n<li class=\"ai-optimize-35\">Lead Shields &amp; Barriers: Protect technicians from radiation exposure.<\/li>\n<li class=\"ai-optimize-36\">Dosimeters: Measure and monitor exposure levels for safety compliance.<\/li>\n<li class=\"ai-optimize-37\">Image Quality Indicators (IQIs): Standard markers used to verify image resolution and inspection quality.<\/li>\n<\/ul>\n<p class=\"ai-optimize-38\">Proper calibration and maintenance of these tools are crucial to ensuring valid results. Additionally, Radiographic Testing setups must comply with international radiation safety standards, such as those set by the IAEA or local regulatory bodies (e.g., BAPETEN in Indonesia).<\/p>\n<h2 class=\"ai-optimize-39\">Types of Radiographic Testing Techniques<\/h2>\n<p class=\"ai-optimize-40\">Radiographic Testing has evolved to include several techniques, each with its own application strengths:<\/p>\n<h3 class=\"ai-optimize-41\">1. Conventional Film Radiography<\/h3>\n<p class=\"ai-optimize-42\">This traditional method uses photographic film to capture radiation. It offers high resolution and is widely accepted by code standards. However, it requires chemical processing and has longer turnaround times.<\/p>\n<h3 class=\"ai-optimize-43\">\u00a02. Computed Radiography (CR)<\/h3>\n<p class=\"ai-optimize-44\">In CR, an image plate replaces the film. After exposure, the plate is scanned using a laser-based digitizer. CR improves workflow and reduces chemical waste.<\/p>\n<h3 class=\"ai-optimize-45\">3. Digital Radiography (DR)<\/h3>\n<p class=\"ai-optimize-46\">Digital Radiography provides real-time imaging through digital sensors. It enables faster decision-making, enhanced flaw detection, and better data management. DR is increasingly preferred in high-volume inspections such as pipeline girth welds.<\/p>\n<h3 class=\"ai-optimize-47\">4. Real-Time Radiography<\/h3>\n<p class=\"ai-optimize-48\">Also called fluoroscopy, this method uses video feeds to view dynamic components under stress. Though costly, it&#8217;s valuable in aerospace and automotive part testing.<br \/>\nInspectors select each technique based on inspection speed, accessibility, regulatory requirements, and cost-efficiency.<\/p>\n<h2 class=\"ai-optimize-49\">Join PetroSync\u2019s Training to Advance Your Expertise<\/h2>\n<p class=\"ai-optimize-50\">In today\u2019s competitive industrial landscape, technical knowledge alone isn\u2019t enough. What sets professionals apart is their commitment to continuous learning\u2014they turn practical experience into structured expertise that others recognize and respect. <a href=\"https:\/\/www.petrosync.com\/\">PetroSync<\/a>\u2019s professional training programs help you grow with clear purpose.<\/p>\n<p class=\"ai-optimize-51\">Whether you&#8217;re looking to build confidence in the field, stay updated with the latest industry standards, or prepare for globally recognized certifications, this is your opportunity to invest in yourself. Our programs connect technical theory with real-world practice, guided by industry experts who understand the challenges you face every day.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>In industries where safety, precision, and compliance are paramount\u2014such as oil and gas, petrochemical, and manufacturing\u2014non-destructive testing (NDT) methods are critical for maintaining asset integrity. One of the most reliable methods to detect internal flaws is Radiographic Testing (RT). Many industries still rely on RT in inspection scenarios, especially when surface-based methods can\u2019t detect internal,<\/p>\n","protected":false},"author":3,"featured_media":4574,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[14],"tags":[524],"class_list":{"0":"post-4573","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-asme","8":"tag-radiographic-testing"},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v25.3 (Yoast SEO v27.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Radiographic Testing Explained for Industry<\/title>\n<meta name=\"description\" content=\"Radiographic testing detects internal flaws in oil and gas components using X-rays or gamma rays for safety and quality assurance.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.petrosync.com\/blog\/radiographic-testing\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Radiographic Testing Explained for Industry\" \/>\n<meta property=\"og:description\" content=\"Radiographic testing detects internal flaws in oil and gas components using X-rays or gamma rays for safety and quality assurance.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.petrosync.com\/blog\/radiographic-testing\/\" \/>\n<meta property=\"og:site_name\" content=\"PetroSync Blog\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/wwwfacebook.com\/PetroSync\/\" \/>\n<meta property=\"article:published_time\" content=\"2025-04-30T07:47:52+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-06-19T04:07:47+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.petrosync.com\/blog\/wp-content\/uploads\/2025\/04\/Radiographic-testing-scaled.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"1340\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"Yudhi Prasetia\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Yudhi Prasetia\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.petrosync.com\\\/blog\\\/radiographic-testing\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.petrosync.com\\\/blog\\\/radiographic-testing\\\/\"},\"author\":{\"name\":\"Yudhi Prasetia\",\"@id\":\"https:\\\/\\\/www.petrosync.com\\\/blog\\\/#\\\/schema\\\/person\\\/9dd6cfc5add245ea9ba13d2bb6aa562f\"},\"headline\":\"Radiographic Testing Explained for Industry\",\"datePublished\":\"2025-04-30T07:47:52+00:00\",\"dateModified\":\"2025-06-19T04:07:47+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.petrosync.com\\\/blog\\\/radiographic-testing\\\/\"},\"wordCount\":763,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.petrosync.com\\\/blog\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.petrosync.com\\\/blog\\\/radiographic-testing\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.petrosync.com\\\/blog\\\/wp-content\\\/uploads\\\/2025\\\/04\\\/Radiographic-testing-scaled.webp\",\"keywords\":[\"radiographic testing\"],\"articleSection\":[\"ASME (American Society of Mechanical Engineers)\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.petrosync.com\\\/blog\\\/radiographic-testing\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.petrosync.com\\\/blog\\\/radiographic-testing\\\/\",\"url\":\"https:\\\/\\\/www.petrosync.com\\\/blog\\\/radiographic-testing\\\/\",\"name\":\"Radiographic Testing Explained for Industry\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.petrosync.com\\\/blog\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.petrosync.com\\\/blog\\\/radiographic-testing\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.petrosync.com\\\/blog\\\/radiographic-testing\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.petrosync.com\\\/blog\\\/wp-content\\\/uploads\\\/2025\\\/04\\\/Radiographic-testing-scaled.webp\",\"datePublished\":\"2025-04-30T07:47:52+00:00\",\"dateModified\":\"2025-06-19T04:07:47+00:00\",\"description\":\"Radiographic testing detects internal flaws in oil and gas components using X-rays or gamma rays for safety and quality assurance.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.petrosync.com\\\/blog\\\/radiographic-testing\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.petrosync.com\\\/blog\\\/radiographic-testing\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.petrosync.com\\\/blog\\\/radiographic-testing\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.petrosync.com\\\/blog\\\/wp-content\\\/uploads\\\/2025\\\/04\\\/Radiographic-testing-scaled.webp\",\"contentUrl\":\"https:\\\/\\\/www.petrosync.com\\\/blog\\\/wp-content\\\/uploads\\\/2025\\\/04\\\/Radiographic-testing-scaled.webp\",\"width\":2560,\"height\":1340,\"caption\":\"Radiographic Testing Explained for Industry\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.petrosync.com\\\/blog\\\/radiographic-testing\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.petrosync.com\\\/blog\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Radiographic Testing Explained for Industry\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.petrosync.com\\\/blog\\\/#website\",\"url\":\"https:\\\/\\\/www.petrosync.com\\\/blog\\\/\",\"name\":\"PetroSync Blog\",\"description\":\"Oil and Gas Training, Course, and Workshop\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.petrosync.com\\\/blog\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.petrosync.com\\\/blog\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.petrosync.com\\\/blog\\\/#organization\",\"name\":\"PetroSync\",\"url\":\"https:\\\/\\\/www.petrosync.com\\\/blog\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.petrosync.com\\\/blog\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.petrosync.com\\\/blog\\\/wp-content\\\/uploads\\\/2022\\\/04\\\/Petrosync-Oil-and-Gas-petrochemical-and-energy-training-2-jpeg.webp\",\"contentUrl\":\"https:\\\/\\\/www.petrosync.com\\\/blog\\\/wp-content\\\/uploads\\\/2022\\\/04\\\/Petrosync-Oil-and-Gas-petrochemical-and-energy-training-2-jpeg.webp\",\"width\":142,\"height\":142,\"caption\":\"PetroSync\"},\"image\":{\"@id\":\"https:\\\/\\\/www.petrosync.com\\\/blog\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/wwwfacebook.com\\\/PetroSync\\\/\",\"https:\\\/\\\/www.instagram.com\\\/petrosync\\\/\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/petrosync-b1159089\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/petrosync\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.petrosync.com\\\/blog\\\/#\\\/schema\\\/person\\\/9dd6cfc5add245ea9ba13d2bb6aa562f\",\"name\":\"Yudhi Prasetia\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/1927b62be666c463ca00b50abc6e592f9da9f20bad67d5b7dcb83f738de67a5e?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/1927b62be666c463ca00b50abc6e592f9da9f20bad67d5b7dcb83f738de67a5e?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/1927b62be666c463ca00b50abc6e592f9da9f20bad67d5b7dcb83f738de67a5e?s=96&d=mm&r=g\",\"caption\":\"Yudhi Prasetia\"},\"description\":\"Results-oriented and thorough SEO specialist with extensive experience in conducting keyword research, developing and implementing digital website promotion strategies and plans, managing campaigns to develop company websites in the digital world, excellent knowledge of marketing techniques and principles, and attentive strong attention to detail.\",\"gender\":\"male\",\"knowsLanguage\":[\"English\",\"Indonesia\"],\"jobTitle\":\"SEO Specialist\",\"worksFor\":\"Yudhi Prasetia\",\"url\":\"https:\\\/\\\/www.petrosync.com\\\/blog\\\/author\\\/yudhiprasetia\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Radiographic Testing Explained for Industry","description":"Radiographic testing detects internal flaws in oil and gas components using X-rays or gamma rays for safety and quality assurance.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.petrosync.com\/blog\/radiographic-testing\/","og_locale":"en_US","og_type":"article","og_title":"Radiographic Testing Explained for Industry","og_description":"Radiographic testing detects internal flaws in oil and gas components using X-rays or gamma rays for safety and quality assurance.","og_url":"https:\/\/www.petrosync.com\/blog\/radiographic-testing\/","og_site_name":"PetroSync Blog","article_publisher":"https:\/\/wwwfacebook.com\/PetroSync\/","article_published_time":"2025-04-30T07:47:52+00:00","article_modified_time":"2025-06-19T04:07:47+00:00","og_image":[{"width":2560,"height":1340,"url":"https:\/\/www.petrosync.com\/blog\/wp-content\/uploads\/2025\/04\/Radiographic-testing-scaled.webp","type":"image\/webp"}],"author":"Yudhi Prasetia","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Yudhi Prasetia","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.petrosync.com\/blog\/radiographic-testing\/#article","isPartOf":{"@id":"https:\/\/www.petrosync.com\/blog\/radiographic-testing\/"},"author":{"name":"Yudhi Prasetia","@id":"https:\/\/www.petrosync.com\/blog\/#\/schema\/person\/9dd6cfc5add245ea9ba13d2bb6aa562f"},"headline":"Radiographic Testing Explained for Industry","datePublished":"2025-04-30T07:47:52+00:00","dateModified":"2025-06-19T04:07:47+00:00","mainEntityOfPage":{"@id":"https:\/\/www.petrosync.com\/blog\/radiographic-testing\/"},"wordCount":763,"commentCount":0,"publisher":{"@id":"https:\/\/www.petrosync.com\/blog\/#organization"},"image":{"@id":"https:\/\/www.petrosync.com\/blog\/radiographic-testing\/#primaryimage"},"thumbnailUrl":"https:\/\/www.petrosync.com\/blog\/wp-content\/uploads\/2025\/04\/Radiographic-testing-scaled.webp","keywords":["radiographic testing"],"articleSection":["ASME (American Society of Mechanical Engineers)"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.petrosync.com\/blog\/radiographic-testing\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.petrosync.com\/blog\/radiographic-testing\/","url":"https:\/\/www.petrosync.com\/blog\/radiographic-testing\/","name":"Radiographic Testing Explained for Industry","isPartOf":{"@id":"https:\/\/www.petrosync.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.petrosync.com\/blog\/radiographic-testing\/#primaryimage"},"image":{"@id":"https:\/\/www.petrosync.com\/blog\/radiographic-testing\/#primaryimage"},"thumbnailUrl":"https:\/\/www.petrosync.com\/blog\/wp-content\/uploads\/2025\/04\/Radiographic-testing-scaled.webp","datePublished":"2025-04-30T07:47:52+00:00","dateModified":"2025-06-19T04:07:47+00:00","description":"Radiographic testing detects internal flaws in oil and gas components using X-rays or gamma rays for safety and quality assurance.","breadcrumb":{"@id":"https:\/\/www.petrosync.com\/blog\/radiographic-testing\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.petrosync.com\/blog\/radiographic-testing\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.petrosync.com\/blog\/radiographic-testing\/#primaryimage","url":"https:\/\/www.petrosync.com\/blog\/wp-content\/uploads\/2025\/04\/Radiographic-testing-scaled.webp","contentUrl":"https:\/\/www.petrosync.com\/blog\/wp-content\/uploads\/2025\/04\/Radiographic-testing-scaled.webp","width":2560,"height":1340,"caption":"Radiographic Testing Explained for Industry"},{"@type":"BreadcrumbList","@id":"https:\/\/www.petrosync.com\/blog\/radiographic-testing\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.petrosync.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Radiographic Testing Explained for Industry"}]},{"@type":"WebSite","@id":"https:\/\/www.petrosync.com\/blog\/#website","url":"https:\/\/www.petrosync.com\/blog\/","name":"PetroSync Blog","description":"Oil and Gas Training, Course, and Workshop","publisher":{"@id":"https:\/\/www.petrosync.com\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.petrosync.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.petrosync.com\/blog\/#organization","name":"PetroSync","url":"https:\/\/www.petrosync.com\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.petrosync.com\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.petrosync.com\/blog\/wp-content\/uploads\/2022\/04\/Petrosync-Oil-and-Gas-petrochemical-and-energy-training-2-jpeg.webp","contentUrl":"https:\/\/www.petrosync.com\/blog\/wp-content\/uploads\/2022\/04\/Petrosync-Oil-and-Gas-petrochemical-and-energy-training-2-jpeg.webp","width":142,"height":142,"caption":"PetroSync"},"image":{"@id":"https:\/\/www.petrosync.com\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/wwwfacebook.com\/PetroSync\/","https:\/\/www.instagram.com\/petrosync\/","https:\/\/www.linkedin.com\/in\/petrosync-b1159089","https:\/\/www.linkedin.com\/company\/petrosync\/"]},{"@type":"Person","@id":"https:\/\/www.petrosync.com\/blog\/#\/schema\/person\/9dd6cfc5add245ea9ba13d2bb6aa562f","name":"Yudhi Prasetia","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/1927b62be666c463ca00b50abc6e592f9da9f20bad67d5b7dcb83f738de67a5e?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/1927b62be666c463ca00b50abc6e592f9da9f20bad67d5b7dcb83f738de67a5e?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/1927b62be666c463ca00b50abc6e592f9da9f20bad67d5b7dcb83f738de67a5e?s=96&d=mm&r=g","caption":"Yudhi Prasetia"},"description":"Results-oriented and thorough SEO specialist with extensive experience in conducting keyword research, developing and implementing digital website promotion strategies and plans, managing campaigns to develop company websites in the digital world, excellent knowledge of marketing techniques and principles, and attentive strong attention to detail.","gender":"male","knowsLanguage":["English","Indonesia"],"jobTitle":"SEO Specialist","worksFor":"Yudhi Prasetia","url":"https:\/\/www.petrosync.com\/blog\/author\/yudhiprasetia\/"}]}},"_links":{"self":[{"href":"https:\/\/www.petrosync.com\/blog\/wp-json\/wp\/v2\/posts\/4573","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.petrosync.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.petrosync.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.petrosync.com\/blog\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.petrosync.com\/blog\/wp-json\/wp\/v2\/comments?post=4573"}],"version-history":[{"count":4,"href":"https:\/\/www.petrosync.com\/blog\/wp-json\/wp\/v2\/posts\/4573\/revisions"}],"predecessor-version":[{"id":4734,"href":"https:\/\/www.petrosync.com\/blog\/wp-json\/wp\/v2\/posts\/4573\/revisions\/4734"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.petrosync.com\/blog\/wp-json\/wp\/v2\/media\/4574"}],"wp:attachment":[{"href":"https:\/\/www.petrosync.com\/blog\/wp-json\/wp\/v2\/media?parent=4573"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.petrosync.com\/blog\/wp-json\/wp\/v2\/categories?post=4573"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.petrosync.com\/blog\/wp-json\/wp\/v2\/tags?post=4573"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}